FFM 4 wing bi-parting folding door system Requires min. Installation space, yet offer max. Clearance width. Designed, constructed and installed to satisfy BSEN and UK standards such as Part M of the building regulations, The Equality Act and BS8300:2009. Supplied with a failsafe system (battery back-up) that enables up to 30 min. Operation in the event of mains failure.

Fail safe system is tested at least every 24 hours. The main drive unit incorporates an auto reverse safety and safety stopping mechanism. Suitable for a wide variety of applications. Installed by ADSA accredited engineers. Product reference: FFM 4 wing bi parting folding door system Product properties  Door configuration: Bi-parting folding  Door clearance width: 800 mm to 1600mm. Door height: 2000mm to 2500mm  Finish: Anodised silver or polyester powder coated to any RAL colour  Drive operation: FFM drive unit for folding wing doors  Glazing: Single glazed 10mm clear toughened glass, double glazed 16mm upon request  Control: Bedis hard wired control unit or 6 position key switch (optional)  Activation: Access control systems, Motion sensors, Manual push pad or touch–less pad. Locking and security: Installation specific; please consult manufacturer.

Door movement guidance: Recessed floor track available upon request Drive system: Auto reverse safety and safety stopping mechanisms. Safety: Combined presence and activation sensing devices to ensure door opening distances are in acc. With BSEN 16005, doors do not close on pedestrians within the threshold area and provide a signal to the door control system. Rear edge sensors (electro sensitive protection equipment ESPE) complying with BSEN 16005 maintain back of door safety and protect pedestrians against crushing edges. Failsafe system (battery back-up) that enables up to 30 min.

Operation in the event of a mains failure. Fail safe system is automatically tested at least every 24 hours. Fire alarm interface enabling door leaves to fail safe open in the event of emergency. BSEN 16005 door sets with a clear opening width of up to 2000mm open by at least 80% within 3 sec. After activation by the activators in the escape direction (or within 5 sec. In the event of the loss of power).

Operation: 24V DC motor with microprocessor controller. Control: Bedis programming key pad.

Door weight: 70 kg (per folding door leaf). Power requirements: 230V single phase. Please note a 13A LIVE neon lit fused spur supply, protected by a 30mA RCD MUST be provided by OTHERS. BSEN 16005 the mains connection must be capable of disconnection to safeguard against unintentional and unauthorised reactivation. Door safety and security: Firmly secured Solid Glazed Barrier acc. With BSEN 16005. Mechanical lock incorporated within door operator.

Recessed floor track, helps improve door security as well as weather sealing. CE approval, TUV NORD, DIN18650-1, DIN 18650-2 (2005 and 2010), DIN EN 60335-1:2007, ISO 9001:2008.

Gilgen SLX sliding door operators are designed, constructed and installed to satisfy BS EN, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Document B and M, The Equality Act 2010 and BS 8300:2009. The integration of a number of technological advancements such as CanBus technology for enhanced operational safety and bluetooth wireless technology for easier access and control ensure the doors are suitability for a wide variety of applications such as retail, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure. All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers. Door profile: 40 mm thick. Nec phone dt300 manual turn mic off.

Drive system: SLX sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety. Safety:. Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety. Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.

Door

Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours. Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.) Operation: 24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements: 230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation.

In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation. Door leaf: - Width: Single sliding:. Standard SLX drive: 700–2000 mm. Heavy duty SLX drive: 800–3000 mm. Heavy duty SLX drive with booster: 1100–3000 mm.

Gilgen Auto Door Manual

Bi parting:. Standard SLX drive: 800–3000 mm. Standard SLX drive with booster: 1000–3000 mm.

Standard SLX drive dual motor: 1100–3000 mm. Heavy duty SLX drive dual motor: 1200–4000 mm.

Standard SLX drive with break out: 1000–2500 mm. Height: 2000–3000 mm - Nominal depending upon location and door panel width and weight. Weight:. 1 x 150 kg (standard SLX drive). 1 x 240 kg (heavy duty SLX drive).

1 x 400 kg (heavy duty SLX drive with booster). 2 x 120 kg (standard SLX drive).

2 x 150 kg (standard SLX drive plus booster or dual motor). 2 x 240 kg (heavy duty SLX drive dual motor).

Gilgen Automatic Door Manual

Configuration (break out solutions only): The bi-parting sliding door system with break out is designed to provide a convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N.

Rear door safety: Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;.

900 mm high, firmly secured, solid glazed barrier, in accordance with BS EN 16005. 2.5 m high, fully glazed pocket screen complying with BS EN 16005. Security: A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer. Control:.

D Bedix hard wired programming key pad (incorporating digital display screen). Designed for installation in a central control panel.

Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes. Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters.

Simple menu based controls. No fixed location required.

Password protected. Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access. F Key: Multi user, compact programmable portable unit enabling restricted personnel access.

Gilgen

Six position key switch. Single point door control but with NO fault identification. Operation: Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems. Glazing:. Single or double glazed with a range of U-values as low as 1.6 W/m²K.

Tinted glazing. For added security glazing complete with bomb blast resistant film can readily be supplied. Glazing complete with etched in logos. Glazed fan lights. Door movement guide:.

Surface mounted fixed point guide enhances efficiency of door movement. Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Recessed floor track: Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. The product information below is from the NBS Plus library of product clauses offered in NBS specification products.

It has been created by NBS for Gilgen Door Systems UK Ltd. Each product clause is authored in NBS format and is intended for inclusion in project specifications. Please note that NBS product guidance is not a replacement for the manufacturer's literature and it is recommended that Gilgen Door Systems UK Ltd be consulted before specifying. To find out more about producing specifications for building projects visit Manufacturer.

Your browser does not support automatic copy to clipboard. Press Ctrl + c (or on a Mac, Command + c) now to copy the selected text.